Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 110484367

Citation: 01004

Citation Type: Other

Abatement Status: X

Initial Penalty: $2,500.00

Current Penalty: $2,000.00

Issuance Date: 11/09/2005

Nr Instances: 10

Nr Exposed: 4

Abatement Date: 12/29/2005

Gravity: 10

Report ID: 0830600

Contest Date:

Final Order:

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 11/22/2005 $2,000.00 12/29/2005 Other  
Penalty Z: Issued 11/09/2005 $2,500.00 12/29/2005 Serious  

Text For Citation: 01 Item/Group: 004 Hazard: ELECTRIC

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical hazards due to improper installation and use of electrical equipment: a) On or about June 6, 2005 and at times prior Timpas Feedyard LLC did not ensure that employees were protected from electrical hazards in the following instances: 1. Intrinsically safe wiring and lighting systems were not maintained and repaired to keep the electrical systems isolated/safe in the grain handling and feed mixing areas. 2. Cords were improperly spliced in the cooker room and the hospital area. 3. Extension cords were used in lieu of permanent wiring systems in the cooking room, the feed mixing area, and the hospital. 4. Panel boxes in the electrical room did not have covers, exposing live conductors. 5. The boiler controls were missing a cover and had strain relief problems. 6. The high power feed lines crossing the roof of the feedmill forced the employees to step over them to do work on the roof auger system. Among other methods, one feasible and acceptable method of abatement to correct this hazard is: a) An examination of the plant's electrical system needs to be done by a qualified electrical contractor and the wiring systems brought back into compliance with the NEC and CFR standards. Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").-Certification

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close