Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1095164.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $1,600.00
Current Penalty: $5,306.00
Issuance Date: 03/24/2016
Nr Instances: 1
Nr Exposed: 12
Abatement Date: 04/28/2016
Gravity: 5
Report ID: 0215800
Contest Date: 04/08/2016
Final Order: 09/18/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 09/18/2017 | $5,306.00 | 04/28/2016 | Serious | |
Penalty | C: Contested | 04/19/2016 | $1,600.00 | 04/28/2016 | Serious | |
Penalty | Z: Issued | 03/24/2016 | $1,600.00 | 04/28/2016 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Throughout the facility, on or about 11/12/15: A program was not developed to protect against unexpected energizing, startup or release of stored energy for machinery including, but not limited to, heat sealers and fill stations. Energy control procedures were not written, training was not performed and lockout devices were not available. Abatement certification must be submitted for this item.