Violation Detail
Standard Cited: 19260704 C Requirements for precast concrete.
This violation item has been deleted.
Inspection Nr: 1080311.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,300.00
Current Penalty: $0.00
Issuance Date: 12/31/2015
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 01/11/2016
Gravity: 10
Report ID: 0111400
Contest Date: 01/27/2016
Final Order: 05/30/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 05/30/2017 | $0.00 | 01/11/2016 | Serious | |
| Penalty | C: Contested | 01/29/2016 | $6,300.00 | 01/11/2016 | Serious | |
| Penalty | Z: Issued | 12/31/2015 | $6,300.00 | 01/11/2016 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.704(c): Lifting inserts which were embedded or otherwise attached to precast concrete members, other than the tilt-up members, were not capable of supporting at least four times the maximum intended load applied or transmitted to them: Location: Jobsite An employee suffered fatal injuries where a lifting point on a moment frame failed