Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1008819.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,500.00
Current Penalty: $5,500.00
Issuance Date: 02/27/2015
Nr Instances: 1
Nr Exposed: 8
Abatement Date: 07/10/2015
Gravity: 5
Report ID: 0728900
Contest Date: 03/25/2015
Final Order: 06/08/2015
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 06/08/2015 | $5,500.00 | 07/10/2015 | Serious | |
| Penalty | C: Contested | 03/26/2015 | $5,500.00 | 07/10/2015 | Serious | |
| Penalty | Z: Issued | 02/27/2015 | $5,500.00 | 07/10/2015 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: At the facility the employer is failing to ensure that employees that are required to use N95 masks when entering the cement truck drum to perform chipping operations pass a fit test.