Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1006932.015
Citation: 01004
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,900.00
Current Penalty: $1,960.00
Issuance Date: 02/19/2015
Nr Instances: 16
Nr Exposed: 6
Abatement Date:
Gravity: 10
Report ID: 0522000
Contest Date: 03/18/2015
Final Order: 03/28/2016
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 03/28/2016 | $1,960.00 | Serious | ||
| Penalty | C: Contested | 03/18/2015 | $4,900.00 | Serious | ||
| Penalty | Z: Issued | 02/19/2015 | $4,900.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes. a: On and before November 6, 2014, located in the rear of the bowling alley, employees retrieving bowling balls and resetting pins were exposed to unguarded pulleys driving the ball return mechanisms for the AMF Model 8270 pin setting machines for each of the 32 bowling lanes.