Violation Detail
Standard Cited: 19100179 N04 I Overhead and gantry cranes.
Inspection Nr: 1609137.015
Citation: 01003D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $7,251.00
Issuance Date: 11/30/2022
Nr Instances: 1
Nr Exposed: 8
Abatement Date: 12/29/2022
Gravity: 1
Report ID: 0636900
Contest Date: 12/27/2022
Final Order: 08/27/2024
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/27/2024 | $7,251.00 | 12/29/2022 | Serious | |
Penalty | C: Contested | 12/28/2022 | $0.00 | 12/29/2022 | Serious | |
Penalty | Z: Issued | 11/30/2022 | $0.00 | 12/29/2022 | Serious |
Text For Citation: 01 Item/Group: 003D Hazard:
29 CFR 1910.179(n)(4)(i): The upper limit switch of each hoist was not tried out under no load, at the beginning of each operator's shift: On or about July 13, 2022, and at times prior thereto in the flooring department, the employer did not ensure the upper limit switch was tested prior to each operator's shift.