Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1247171.015
Citation: 01003D
Citation Type: Serious
Abatement Date: 09/21/2017 2
Initial Penalty: $8,149.00
Current Penalty: $0.00
Issuance Date: 08/04/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 08/22/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/22/2017 | $0.00 | 09/21/2017 | Serious | |
Penalty | Z: Issued | 08/04/2017 | $8,149.00 | 09/21/2017 | Serious |
Text For Citation: 01 Item/Group: 003D Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: At 9832 Evergreen Industrial Drive, St. Louis, MO 63123, specifically inside of the Print & Roll Stock Department, employee(s) failed to de-energize the Retroflex Single-Color Flexo Printer, m/n 20114613, a.k.a. Press #17, prior to performing servicing and repair to the PVA Station. A multiple amputation occurred on or about 07/14/17.