Violation Detail
Standard Cited: 19261101 G08 I Asbestos
Inspection Nr: 1239612.015
Citation: 01003D
Citation Type: Other
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/30/2017
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 12/06/2017
Gravity:
Report ID: 0521700
Contest Date: 12/20/2017
Final Order: 02/28/2019
Related Event Code (REC): C
Emphasis:
Substance: 9020
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/28/2019 | $0.00 | 12/06/2017 | Other | |
Penalty | C: Contested | 12/22/2017 | $0.00 | 12/06/2017 | Serious | |
Penalty | Z: Issued | 11/30/2017 | $0.00 | 12/06/2017 | Serious |
Text For Citation: 01 Item/Group: 003D Hazard:
29 CFR 1926.1101(g)(8)(i): For jobs removing vinyl and asphalt flooring materials which contain asbestos of for which buildings constructed no later than 1980, where the employer did not verify the absence of asbestos containing material pursuant to 29 CFR 1926.1101(g)(8)(i)(I), the employer did not ensure that employees complied with work practices described in 29 CFR 1926.1101(g)(8)(i)(A) through (g)(8)(i)(I) and that employees were trained in these practices pursuant to 29 CFR 1926.1101(k)(9): a) On or about June 7, 2017, at the above located worksite employees were required to remove 12 inch floor tiles and mastic that contained 0.4% to 6.0% asbestos (Class II asbestos work) in the main first floor north-south corridor. The employer did not ensure that employees complied with the work practices listed in subparagraphs (A) through (I) of this section and trained as required by 29 CFR 1926.1101(k)(9). Employees removing asbestos containing floor tile were thereby exposed to the hazards associated with airborne asbestos.