Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1082893.015
Citation: 01003D
Citation Type: Serious
Abatement Date: 11/03/2015 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/07/2015
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0418400
Contest Date:
Final Order: 10/28/2015
Emphasis:
Substance: 9135
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/28/2015 | $0.00 | 11/03/2015 | Serious | |
Penalty | Z: Issued | 10/07/2015 | $0.00 | 11/03/2015 | Serious |
Text For Citation: 01 Item/Group: 003D Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (Construction Reference 1926.103) (a) Pooler construction site, on or about and at times preceding to August 4, 2015, the employer had not conducted fit testing for required use of 3M half mask cartridge respirators being used for R17 and R13 insulation installation.