Violation Detail
Standard Cited: 19260502 D15 Fall protection systems criteria and practices.
Inspection Nr: 959184.015
Citation: 01003C
Citation Type: Serious
Abatement Date: 04/21/2014 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/15/2014
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0524200
Contest Date:
Final Order: 05/08/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/08/2014 | $0.00 | 04/21/2014 | Serious | |
Penalty | Z: Issued | 04/15/2014 | $0.00 | 04/21/2014 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: a) The employer did not ensure that the anchorage used by employees as an attachment point for personal fall arrest system was capable of supporting at least 5,000 pound per employee attached to it. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.