Violation Detail
Standard Cited: 19100179 L01 Overhead and gantry cranes.
Inspection Nr: 1797905.015
Citation: 01003C
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/04/2025
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 06/16/2025
Gravity: 5
Report ID: 0830600
Contest Date: 04/29/2025
Final Order: 07/18/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 07/18/2025 | $0.00 | 06/16/2025 | Other | |
| Penalty | C: Contested | 04/30/2025 | $0.00 | 05/02/2025 | Serious | |
| Penalty | Z: Issued | 04/04/2025 | $0.00 | 05/02/2025 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.179(l)(1): A preventive maintenance program based on the crane manufacturer's recommendations was not established: a) On or about October 23, 2024, and at time prior, the employer did not ensure that a preventive maintenance program based on the crane manufacturer's recommendations for the overhead bridge crane on the west side of the shop was established. b) On or about October 23, 2024, and at times prior the employer did not ensure that a preventive maintenance program based on the crane manufacturer's recommendations for the overhead bridge crane on the east side of the shop was established.