Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1707720.015
Citation: 01003C
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/06/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 04/02/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/02/2024 | $0.00 | Serious | ||
Penalty | Z: Issued | 03/06/2024 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves. On or about November 3, 2023, at an establishment located at W694 White Ridge Road in Berlin, Wisconsin, the employer did not protect employees from the projecting shaft ends of a motor located at the sample port outside the back door of the shaker room before the silos.