Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1694706.015
Citation: 01003C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/03/2024
Nr Instances: 1
Nr Exposed: 21
Abatement Date: 01/16/2024
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 01/11/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/11/2024 | $0.00 | 01/16/2024 | Serious | |
Penalty | Z: Issued | 01/03/2024 | $0.00 | 01/16/2024 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.147(c)(7)(i)(B): Each affected employee shall be instructed in the purpose and use of the energy control procedure. (a) On or about August 30, 2023, affected employees operating Rotational Molding Machines were not trained in the recognition of applicable hazardous energy sources and energy isolation control, exposing employees to electrical, pneumatic, hydraulic, gravitational energy sources and other hazards associated with the work being performed in the facility.