Violation Detail
Standard Cited: 19100219 F01 Mechanical power-transmission apparatus.
Inspection Nr: 1675578.015
Citation: 01003C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,938.00
Current Penalty: $4,687.00
Issuance Date: 09/29/2023
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 03/26/2024
Gravity: 10
Report ID: 0213900
Contest Date: 10/24/2023
Final Order: 01/26/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 03/27/2024 | $4,687.00 | 03/26/2024 | Serious | |
Penalty | J: ALJ Decision | 01/26/2024 | $4,687.00 | 03/26/2024 | Serious | |
Penalty | C: Contested | 12/27/2023 | $10,938.00 | 10/26/2023 | Serious | |
Penalty | Z: Issued | 09/29/2023 | $10,938.00 | 10/26/2023 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): a) Innovative Metals Inc./Lockformer machine Area: The LOCKFORMER Flush lock (GREEN) machine MODEL# GEM 3300, S/N SP1182 did not have a guard to enclose the ingoing nip point of exposed gears, observed on or about 06/07/2023. b) Innovative Metals Inc./Lockformer machine Area: The LOCKFORMER Batten Tile (BLUE) Model # 2916, did not have a guard to enclose the ingoing nip point of exposed gears, observed on or about 06/07/2023.