Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1652224.015
Citation: 01003C
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,465.00
Current Penalty: $0.00
Issuance Date: 07/07/2023
Nr Instances: 1
Nr Exposed: 18
Abatement Date:
Gravity: 5
Report ID: 0522000
Contest Date:
Final Order: 07/20/2023
Related Event Code (REC): C
Emphasis:
Substance: 0040
Substance: 1060
Substance: 2440
Substance: 2460
Substance: 2590
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/20/2023 | $0.00 | Serious | ||
Penalty | Z: Issued | 07/07/2023 | $4,465.00 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. (a) On or about 02/23/2023, the employer did not provide fit testing prior to requiring the use of respirators for painters who were required to wear 3M tight fitting half face respirators, such as but not limited to 3M 6000 series with 3M 6001 organic vapor and 3M 60921 P100/OV cartridges.