Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1618348.015
Citation: 01003C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/16/2022
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 02/06/2023
Gravity: 1
Report ID: 0626700
Contest Date:
Final Order: 01/18/2023
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/18/2023 | $0.00 | 02/06/2023 | Serious | |
| Penalty | Z: Issued | 12/16/2022 | $0.00 | 02/06/2023 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. a) On or about August 12, 2022, in the Building B at Continental Warehouse facility, located in Alvin, TX, the employer did not ensure that the employees using the face piece respirator were fit tested prior to initial use and at least annually thereafter.