Violation Detail
Standard Cited: 19100147 D06 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1501662.015
Citation: 01003C
Citation Type: Serious
Abatement Date: 05/24/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/30/2021
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 05/25/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 04/30/2021 | $0.00 | 05/24/2021 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.147(d)(6):Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee did not verify that isolation and de-energization of the machine or equipment had been accomplished. a) Cooper Tire & Rubber Co., North Air Dryer - On or about November 4, 2020, employees installing a valve on the intake header of the air dryer did not verify if the air dryer was depressurized before attempting to remove a coupler and flange from the intake header, exposing employees to a struck-by hazard.