Violation Detail
Standard Cited: 19100107 C05 Spray finishing using flammable and combustible materials.
Inspection Nr: 1466507.015
Citation: 01003C
Citation Type: Serious
Abatement Date: 10/19/2020 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/31/2020
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC): C
Gravity: 5
Report ID: 0112000
Contest Date:
Final Order: 09/28/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/28/2020 | $0.00 | 10/19/2020 | Serious | |
Penalty | Z: Issued | 08/31/2020 | $0.00 | 10/19/2020 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.107(c)(5): 29 CFR 1910.107(c)(5): Electrical equipment not approved for locations containing both deposits of readily ignitable residues and explosive vapors was present in spraying area(s): ADHESIVE SPRAY AREA: On or about and at times prior to March 2, 2020, the following equipment was available for use and was not rated for use where Category 2 flammable liquids such as 3M PB938 High Performance Spray Adhesive were sprayed: 1. Dewalt DW713 Compound Miter Saw 2. Porter Cable 360VS Variable Speed Belt Sander