Violation Detail
Standard Cited: 19100147 C06 I C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1395446.015
Citation: 01003C
Citation Type: Serious
Abatement Date: 09/03/2019 2
Initial Penalty: $13,260.00
Current Penalty: $0.00
Issuance Date: 08/07/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): C
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 08/30/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/30/2019 | $0.00 | 09/03/2019 | Serious | |
Penalty | Z: Issued | 08/07/2019 | $13,260.00 | 09/03/2019 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.147(c)(6)(i): Where lockout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. a) On or about April, 16, 2019, the employer did not ensure that the employer's periodic inspection of the specific energy control procedures utilized by employee, on equipment such as but not limited to, the Worthington welding positioner Serial No. 33112238, located on the production floor, were adequate in that it did not include a review between the inspector and each authorized employee.