Violation Detail
Standard Cited: 19100219 F01 Mechanical power-transmission apparatus.
Inspection Nr: 1344589.015
Citation: 01003C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/06/2018
Nr Instances: 2
Nr Exposed: 10
Abatement Date: 02/01/2019
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 12/04/2018
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | $0.00 | 02/01/2019 | Serious | ||
Penalty | I: Informal Settlement | 12/04/2018 | $0.00 | 01/04/2019 | Serious | |
Penalty | Z: Issued | 11/06/2018 | $0.00 | 11/16/2018 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): a. Alkon Corporation - Fremont, Ohio: On or about September 6, 2018, the employer did not ensure that feed gears of the 1014 Davenport #8 were guarded to protect employees from being injured by the nip points and moving parts. b. Alkon Corporation - Fremont, Ohio: On or about September 6, 2018, the employer did not ensure that the feed gears of the 1016 Davenport #9 were guarded to protect employees from being injured by the nip points and moving parts.