Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1177830.015
Citation: 01003C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/03/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 04/07/2017
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 03/29/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/29/2017 | $0.00 | 04/07/2017 | Serious | |
Penalty | Z: Issued | 03/03/2017 | $0.00 | 04/07/2017 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: A.) Presque Isle Wine Cellars, Inc., 9440 West Main Street, North East, PA 16428, on or about September 15, 2016 and times prior thereto: Employees perform service and maintenance activities on equipment including, but not limited to, an auger, crusher and must pump. The authorized employees had not received training.