Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1175958.015
Citation: 01003C
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/18/2016
Nr Instances: 1
Nr Exposed: 7
Abatement Date:
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 12/20/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/20/2016 | $0.00 | Serious | ||
Penalty | Z: Issued | 11/18/2016 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) Band Saw Work Area - on or about September 8, 2016, employees operated a HA-250W Amada horizontal band saw that had an unguarded vertical belt that was less than seven (7) feet from the floor.