Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1154983.015
Citation: 01003C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/28/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/17/2017
Gravity: 5
Report ID: 0524500
Contest Date: 12/22/2016
Final Order: 04/17/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/17/2017 | $0.00 | 05/17/2017 | Serious | |
Penalty | C: Contested | 01/20/2017 | $0.00 | 12/28/2016 | Serious | |
Penalty | Z: Issued | 11/28/2016 | $0.00 | 12/28/2016 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: On or about June 14, 2016, employees at Boyd Mechanical Toggle Press 3 (No. 1030) were exposed to crush-by and burn hazards when they reached into the die opening and "scratched" the plates to remove green brick debris, lubricated the surfaces (top tie, bottom die, and die cavity), and greased components, and the employer did not ensure isolation devices for the electricity, pneumatic, thermal, and mechanical energies were used.