Violation Detail
Standard Cited: 19100027 C04 Scaffolds and rope descent systems.
This violation item has been deleted.
Inspection Nr: 1005350.015
Citation: 01003C
Citation Type: Serious
Abatement Date: 05/22/2015
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/17/2015
Nr Instances: 40
Nr Exposed: 6
Related Event Code (REC):
Gravity: 5
Report ID: 0830500
Contest Date:
Final Order: 05/04/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/04/2015 | $0.00 | 05/22/2015 | Serious | |
Penalty | Z: Issued | 04/17/2015 | $0.00 | 05/22/2015 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.27(c)(4): The employer did not install fixed ladders with at least 7 inches of clearance from the centerline of the rung to the nearest permanent object in the back of the ladder. (a)Cyclone Rig #17, 05-045-22491-00, Parachute, CO, 81635: On and before October 21st, 2014, the employer did not ensure the fixed ladder had at least 7 inches of clearance from the centerline of the rung to the nearest permanent object in the back of the ladder. The ladder consisted of 1-1/2 inch angle iron which used as rungs to access the upper portion of each "A" leg. Each piece of angle iron was welded directly to the derrick "A" legs. The condition exposed employees to falls, cuts, lacerations, and bruises, while climbing the two ladders.