Violation Detail
Standard Cited: 19100421 F01 III Pre-dive procedures.
Inspection Nr: 980215.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $0.00
Issuance Date: 12/09/2014
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 12/15/2014
Gravity: 10
Report ID: 0418800
Contest Date: 01/02/2015
Final Order: 09/02/2015
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | R: Review Commission | 09/02/2015 | $0.00 | 12/15/2014 | Serious | |
| Penalty | C: Contested | 01/08/2015 | $7,000.00 | 12/15/2014 | Serious | |
| Penalty | Z: Issued | 12/09/2014 | $7,000.00 | 12/15/2014 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.421(f)(1)(iii): Dive team members were not briefed on any unusual hazards or environmental conditions likely to affect the safety of the diving operation, (is applicable to the construction standard by 29 CFR 1926.1081 that incorporates the General Industry requirement): On or about June 10, 2013, at the above addressed job site, the employer did not brief the dive team members on the hazards associated with diving in limited visibility in the excavation. 1. AT&T Conduit 2. Exposed rebar from the broken RCP 3. Zero visibility 4. Working with a five inch diameter hose connected to a dewatering water pump