Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 853963.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/07/2013
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 04/02/2013
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 04/02/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/02/2013 | $0.00 | 04/02/2013 | Serious | |
| Penalty | Z: Issued | 03/07/2013 | $0.00 | 04/02/2013 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): a) On or about 1/21/2013, Building 140: Belts used to power the drive conveyor on the out feed side of a saw for the Wean Draw Bench were not adequately guarded. Abatement certification is required for this item.