Violation Detail
Standard Cited: 19100107 G01 Spray finishing using flammable and combustible materials.
Inspection Nr: 662678.015
Citation: 01003B
Citation Type: Serious
Abatement Date: 12/16/2012 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/13/2012
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): C
Gravity: 1
Report ID: 0317700
Contest Date:
Final Order: 12/04/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/04/2012 | $0.00 | 12/16/2012 | Serious | |
Penalty | Z: Issued | 11/13/2012 | $0.00 | 12/16/2012 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.107(g)(1): Spraying was conducted outside of predetermined spraying areas. a) Shop Area, Weatherford U.S. L.P., 134 Wickwire Way, Towanda, PA: On or about October 1, 2012, employees spray painted equipment outside of the predetermined spray area as evidenced by the overspray residue on the building floor. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.