Violation Detail
Standard Cited: 19100263 F03 Bakery equipment.
Inspection Nr: 1804050.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,550.00
Current Penalty: $0.00
Issuance Date: 05/05/2025
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 05/15/2025
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 05/28/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/28/2025 | $0.00 | 05/15/2025 | Serious | |
Penalty | Z: Issued | 05/05/2025 | $16,550.00 | 05/15/2025 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.263(f)(3): Rear cover(s) of the divider(s) were not provided with a limit switch to prevent machine operation while the cover(s) were open: a. On or about February 4, 2025, Production Department, the employer failed to provide a limit switch on the Werner & Pfleiderer Divider on Line 3 that would prevent machine operation while the cover was open. An employee was injured while attempting to remove a jam and the cover was able to open three inches before the machine stopped, thereby the employee received a fingertip amputation.