Violation Detail
Standard Cited: 19100184 I01 Slings.
Inspection Nr: 1780407.015
Citation: 01003B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/27/2025
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 04/04/2025
Gravity: 5
Report ID: 0728900
Contest Date:
Final Order: 03/12/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/12/2025 | $0.00 | 04/04/2025 | Other | |
| Penalty | Z: Issued | 02/27/2025 | $0.00 | 03/19/2025 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.184(i)(1): Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material: On or about October 7, 2024, it was identified that employees engaged in pretensioning activities at Coreslab Structures (Omaha) Inc. located at 802 Alliance Road, Bellevue, Nebraska were exposed to struck-by hazards in that identification markings were not legible on the synthetic web sling supporting the hydraulic jacking ram. Instances included, but were not limited to the synthetic web slings used during: i. Daily operations in building 1 where employees used the hydraulic jacking ram; G. T. Bynum CO. Model M P U28, Serial number: 122297 and ii. Daily operations in building 2 where employees used the hydraulic jacking ram; G. T. Bynum CO., Model: M P U2, Serial number: 111396.
Translate