Violation Detail
Standard Cited: 19100184 F01 Slings.
Inspection Nr: 1766061.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/02/2024
Nr Instances: 1
Nr Exposed: 13
Abatement Date:
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 10/29/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/29/2024 | $0.00 | Serious | ||
Penalty | Z: Issued | 10/02/2024 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.184(f)(1): Wire-rope slings did not have permanently affixed and legible identification markings as prescribed by the manufacturer that indicated the recommended safe working load for the type(s) of hitch(es) used, the angle upon which it is based, and the number of legs if more than one: a. STAR Turbine, Inc. - Marion, Ohio: On or about August 1, 2024, the employer did not ensure that the two wire rope slings, used a Bay 2 to lift packing ring parts was equipped with permanently affixed identification to include information such as, but not limited to, the sling's safe working load for the type of hitch used, the angle upon which it is based, and number of legs. No additional abatement information is needed for this item.