Violation Detail
Standard Cited: 19260652 G01 III Requirements for protective systems.
Inspection Nr: 1750946.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/27/2024
Nr Instances: 2
Nr Exposed: 1
Abatement Date: 10/09/2024
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 10/23/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 09/27/2024 | $0.00 | 10/09/2024 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1926.652(g)(1)(iii): Employees shall be protected from the hazard of cave-ins when entering or exiting the areas protected by shields: a) On or about May 28, 2024, at a worksite located along Mid Valley Road, De Pere, Wisconsin; an employee entering and exiting the trench box was not protected from potential cave-in hazards as the ladder did not extend out beyond the hazardous area nor was additional trench protection provided. b) On or about May 29, 2024, at a worksite located along Mid Valley Road, De Pere, Wisconsin; an employee entering and exiting the trench box was not protected from potential cave-in hazards as the ladder did not extend out beyond the hazardous area nor was additional trench protection provided.