Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1712096.015
Citation: 01003B
Citation Type: Serious
Abatement Date: 05/01/2024 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/28/2023
Nr Instances: 1
Nr Exposed: 16
Related Event Code (REC):
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 01/10/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 02/26/2024 | $0.00 | 05/01/2024 | Serious | |
Penalty | I: Informal Settlement | 01/10/2024 | $0.00 | 03/01/2024 | Serious | |
Penalty | Z: Issued | 12/28/2023 | $0.00 | 01/12/2024 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Cheese department; Energy isolating device(s) were not operated in such a manner as to isolate energy source(s) prior to performing servicing activities such as but not limited to inserting or removing the curd forks from the agitator.