Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1706050.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/29/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 1
Report ID: 0521400
Contest Date: 04/19/2024
Final Order: 10/07/2024
Related Event Code (REC): C
Emphasis:
Substance: T405
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/07/2024 | $0.00 | Serious | ||
Penalty | C: Contested | 04/19/2024 | $0.00 | Serious | ||
Penalty | Z: Issued | 03/29/2024 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.134(f)(2):The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. On or about October 24, 2023, employees were exposed to respiratory stressors associated with being allowed to wear GVS Elipse Half-Face Respirator with filters, and 3M 6800 Full Face Respirator with filters, . Employees are required to wear the respirator to protect from exposure to Polyester / Triglycidyl Isocyanurate H.G. when cleaning the spray booth. The employees were not fit tested prior to the initial use of the respirator. This item was corrected during the inspection.