Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1697523.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,813.00
Current Penalty: $0.00
Issuance Date: 01/04/2024
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 01/24/2024
Gravity: 5
Report ID: 0522000
Contest Date:
Final Order: 01/24/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/24/2024 | $0.00 | 01/24/2024 | Serious | |
Penalty | Z: Issued | 01/04/2024 | $7,813.00 | 01/24/2024 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.219(c)(4)(i):Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves. a.) On or about September 7, 2023, the employer failed to ensure that shaft ends on laminator 1 did not protrude less than half of the diameter of the shaft as a result employees were exposed to caught by and entanglement hazards.