Violation Detail
Standard Cited: 19100147 F01 V The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1654794.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/30/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 09/29/2023
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/29/2023 | $0.00 | Serious | ||
Penalty | Z: Issued | 08/30/2023 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.147(f)(1)(v): All systems were not de-energized and energy control measures reapplied in accordance with paragraph (d) of this section to continue the servicing and/or maintenance: a) At the amusement park, where energy control procedures were not reapplied after the 22M Giant Loop roller coaster was repositioned during an inspection.