Violation Detail
Standard Cited: 19100219 M01 I Mechanical power-transmission apparatus.
Inspection Nr: 1653624.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,278.00
Current Penalty: $0.00
Issuance Date: 08/15/2023
Nr Instances: 6
Nr Exposed: 2
Abatement Date: 01/02/2024
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 09/05/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/05/2023 | $0.00 | 01/02/2024 | Serious | |
Penalty | Z: Issued | 08/15/2023 | $12,278.00 | 09/13/2023 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.219(m)(1)(i): Standard conditions shall be secured by the use of the following materials. Expanded metal, perforated or solid sheet metal, wire mesh on a frame of angle iron, or iron pipe securely fastened to floor or to frame of machine. On or about February 21, 2023, at an establishment located at 1097 Ehlers Street, in Neenah, Wisconsin; in the Display Area for the FMC 3001 Flexo Press, S/N: 3833, the expanded metal guards on each of the print decks was secured with a hinge which did not protect from being inadvertently dislodged or removed exposing employees to caught between hazards.