Violation Detail
Standard Cited: 19100219 F01 I Mechanical power-transmission apparatus.
Inspection Nr: 1640584.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/10/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 03/30/2023
Gravity: 5
Report ID: 0112600
Contest Date:
Final Order: 03/09/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/09/2023 | $0.00 | 03/30/2023 | Serious | |
| Penalty | Z: Issued | 02/10/2023 | $0.00 | 03/30/2023 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.219(f)(1)(i): Gears were not guarded by a complete enclosure. Plant 9, 118 River Road, Leeds MA: On December 22, 2022 and at times prior, employees were exposed to the hazards of unguarded power transmission gears when they operated the Spiel Inline Notebook Punching and Binding machine that had its manufacturer-provided panel guards removed.