Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1566322.015
Citation: 01003B
Citation Type: Other
Abatement Date: 05/12/2022 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/21/2022
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): R
Gravity: 5
Report ID: 0523900
Contest Date:
Final Order: 05/12/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/12/2022 | $0.00 | 05/12/2022 | Other | |
Penalty | Z: Issued | 04/21/2022 | $0.00 | 05/12/2022 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: (a) In the fabrication shop; On or about November 22, 2021, the pulley housing cover for the Bridgeport milling machine, S/N J-114946, had large openings on both the left and right side of the cover, creating exposure to in-going nip points on the pulleys and belt.