Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1521220.015
Citation: 01003B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/09/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/04/2021
Gravity: 5
Report ID: 0830300
Contest Date:
Final Order: 10/05/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/05/2021 | $0.00 | 10/04/2021 | Serious | |
Penalty | Z: Issued | 09/09/2021 | $0.00 | 10/04/2021 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) On or about March 15, 2021, and at times prior, for the employees exposed to amputation hazards where the lockout/tagout procedure for the Prater Industries, Inc. powdered sugar mill did not address potential stored capacitor energy at 7525 Red River Road in Wahpeton, North Dakota.