Violation Detail
Standard Cited: 19260452 W06 I Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1495724.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,288.00
Current Penalty: $0.00
Issuance Date: 03/31/2021
Nr Instances: 1
Nr Exposed: 9
Abatement Date: 04/26/2021
Gravity: 10
Report ID: 0625700
Contest Date: 04/27/2021
Final Order: 09/02/2022
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/02/2022 | $0.00 | 04/26/2021 | Serious | |
Penalty | C: Contested | 05/05/2021 | $12,288.00 | 04/26/2021 | Serious | |
Penalty | Z: Issued | 03/31/2021 | $12,288.00 | 04/26/2021 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1926.452(w)(6)(i): Employee(s) were allowed to ride on scaffolds when the surface on which the scaffold was moved was not within 3 degrees of level, and/or not free of pits, holes, and obstructions: a) Inside the water tank: On October 5, 2020, employees rode a five-tier Betco fabricated frame scaffold where the tank floor had an approximately twelve degree slope at the perimeter, three approximately 9-inch deep by 24-inch diameter holes, and obstructions including plywood boards.