Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1452023.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/04/2020
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 03/02/2020
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 02/25/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/25/2020 | $0.00 | 03/02/2020 | Serious | |
| Penalty | Z: Issued | 02/04/2020 | $0.00 | 03/02/2020 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o). On 12/19/2019, at the Sandersville location, belts and pulleys that were on floor levels were not guarded at the 50 in. line in the production area.
Translate