Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
This violation item has been deleted.
Inspection Nr: 1447339.015
Citation: 01003B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/03/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/29/2020
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 05/08/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/08/2020 | $0.00 | 04/29/2020 | Serious | |
| Penalty | Z: Issued | 04/03/2020 | $0.00 | 04/29/2020 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Delphi robotic cell: On or about November 16, 2019, employees inside the cell enclosure were not protected from the point of operation of the power molding press when reaching into the point of operation to clear a jam. This exposed the employee to an amputation injury.