Violation Detail
Standard Cited: 19260651 J02 Specific Excavation Requirements.
This violation item has been deleted.
Inspection Nr: 1439804.015
Citation: 01003B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/21/2020
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 05/01/2020
Gravity: 10
Report ID: 0830300
Contest Date: 05/05/2020
Final Order: 11/23/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 11/23/2020 | $0.00 | 05/01/2020 | Serious | |
Penalty | C: Contested | 07/21/2020 | $0.00 | 05/01/2020 | Serious | |
Penalty | Z: Issued | 04/21/2020 | $0.00 | 05/01/2020 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: (a) On or about October 23, 2019, and at times prior, for the employees constructing an outfall structure in an excavation 16 feet or more in depth in the vicinity of Fourth Avenue NW & Tenth Street NW in Minot, North Dakota.