Violation Detail
Standard Cited: 19150073 F Guarding of deck openings and edges.
Inspection Nr: 1409604.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/29/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 1032700
Contest Date:
Final Order: 08/21/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/21/2019 | $0.00 | Serious | ||
Penalty | Z: Issued | 07/29/2019 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1915.73(f): Sections of bilges from which floor plates or gratings have been removed were not guarded by guardrails except where they would interfere with work in progress. If these open sections are in a walkway at least two 10-inch planks placed side by side, or equivalent, shall be laid across the opening to provide a safe walking surface. (a) Fishing Vessel (FV) Progress - Engine Room - On or about June 17th, 2019 and at times prior thereto, employees were exposed to falls of approximately 9' while working in the engine room.