Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1399494.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/23/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0213900
Contest Date: 11/19/2019
Final Order: 02/24/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 02/24/2020 | $0.00 | Serious | ||
Penalty | C: Contested | 11/19/2019 | $0.00 | Serious | ||
Penalty | Z: Issued | 10/23/2019 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: a) Wilmad LabGlass Inc. DBA SP Scienceware - Grinding Area: The inside Diameter #22 machine had an unguarded belt and pulley, observed on or about 05/08/2019. b) Wilmad LabGlass Inc. DBA SP Scienceware : The Concentric machine Model #102T5K-132 (Cincinnati Milling Machine did not have a guard to enclose the exposed pulleys and belts, observed on or about 05/08/2019.