Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1377408.015
Citation: 01003B
Citation Type: Serious
Abatement Date: 09/06/2019 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/06/2019
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 5
Report ID: 0213600
Contest Date: 08/28/2019
Final Order: 05/07/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 05/07/2020 | $0.00 | 09/06/2019 | Serious | |
Penalty | C: Contested | 09/04/2019 | $0.00 | 09/06/2019 | Serious | |
Penalty | Z: Issued | 08/06/2019 | $0.00 | 09/06/2019 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: a) On or about 02/11/19 in the packaging area; employees were exposed to caught in hazards during the set-up, change over, cleaning and sanitation of the production equipment, such as but limited to, weigh dumpers and pouch filler machines on Line #1 - Solpac, Line #2 continuous packer, and Line # 3- PPI Leepack, when the employer did not develop equipment specific procedures to include, but not limited to: the energy sources (pneumatic, electric) and other steps as required to control hazardous energy prior to conducting these activities. ABATEMENT CERTIFICATION REQUIRED