Violation Detail
Standard Cited: 19260502 F01 II Fall protection systems criteria and practices.
Inspection Nr: 1365680.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/25/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 02/08/2019
Gravity: 5
Report ID: 0521400
Contest Date:
Final Order: 02/26/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/26/2019 | $0.00 | 02/08/2019 | Serious | |
Penalty | Z: Issued | 01/25/2019 | $0.00 | 02/08/2019 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1926.502(f)(1)(ii): When mechanical equipment was being used, the warning line was not erected at least 6 feet (1.8 m) from the roof edge which is parallel to the direction of mechanical equipment operation, and at least 10 feet (3.1 m) from the roof edge which is perpendicular to the direction of mechanical equipment operation. On or about December 12, 2018, employees using mechanical equipment did not have flags installed 10 feet from the roof edge, exposing employees to a fall of 14.9 feet. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).