Violation Detail
Standard Cited: 19260652 A01 Requirements for protective systems.
Inspection Nr: 1345325.015
Citation: 01003B
Citation Type: Serious
Abatement Date: 12/12/2018 5
Initial Penalty: $5,174.00
Current Penalty: $0.00
Issuance Date: 11/15/2018
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 12/12/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/12/2018 | $0.00 | 12/12/2018 | Serious | |
Penalty | Z: Issued | 11/15/2018 | $5,174.00 | 12/12/2018 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: a) GPS Coordinates 44.087856-111.279521: On September 4, 2018, and at times prior thereto, employees were working in a trench that was approximately 7.0 - 10 feet in depth, and did not have any protective system in place. Abatement certification and documentation ARE required for this item.