Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1330241.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/09/2018
Nr Instances: 1
Nr Exposed: 15
Abatement Date: 11/27/2018
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 10/22/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/22/2018 | $0.00 | 11/27/2018 | Serious | |
Penalty | Z: Issued | 10/09/2018 | $0.00 | 11/27/2018 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees. On 7/17/18, at the Acworth facility, not all authorized employees performing service and maintenance to equipment affixed a lock to each energy isolating device. i.e. at the Audit booth only 1 lock was hung for 3 employees performing service to the equipment.