Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1285525.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/24/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/20/2018
Gravity: 5
Report ID: 0213900
Contest Date: 09/06/2018
Final Order: 01/30/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 01/30/2019 | $0.00 | 06/20/2018 | Serious | |
Penalty | C: Contested | 09/10/2018 | $0.00 | 06/20/2018 | Serious | |
Penalty | Z: Issued | 05/24/2018 | $0.00 | 06/20/2018 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: a) JVK Operations, Ltd. - Dryer area: The right side of the Lavatec dryer #1, Type T56G/u, S/N 7560319 has a guard missing to cover a belt and pulley, observed on or about 12/19/2017.